8. Select the file containing the firmware to be transferred, confirming this with the Open key.
1
2
ile containing the firmware to be transferred
Figure A - 4 Display for selecting f
9. Select the Send key and wait until transfer of the firmware has been completed.
Figure A - 5 Key to send the firmware transfer
10. Calibrate the photosensors. See the section
"CALIBRATING THE PHOTOSENSORS" on page 4 -
18.
Calibrate the scanner. See the section
"Calibrating the scanner" on page 4 -
28.
11. Print the Self Test again, checking that the firmware release is that required.

Forced loading of firmware

Before proceeding to force loading of the firmware, contact Technical Support
Mail box: Banking.Printers@Olivetti.com
XZA4219-05
Service Manual
A-7