CIS assy (upper scanner) disassembly/reassembly

1. Remove the casing. See the section
2. Remove the upper mechanical assy. See the section
page 7 -
11.
3. Remove the roller assy. See the section
4. Remove the two snap rings (1).
5. Remove the CIS assy (2) lifting it and taking care not to mislay the spring (3).
1
Figure 7 - 47 Removing the CIS unit
6. Disconnect the cable (4) from the CIS (2) taking great care not to damage the connectors (use a slotted
screwdriver as indicated in the figure).
Figure 7 - 48
Disconnecting the CIS cable
XZAC4219-05
"Casing disassembly/reassembly" on page 7 -
"Roller assy (upper scanner) disassembly/reassembly" on page 7 -
4
Service Manual
"Upper mechanical assy disassembly/reassembly" on
2
3
2
4.
31.
1
7-33