Olivetti PR2 PLUS Service Manual page 70

Table of Contents

Advertisement

If the horizontal magnetic option is present
OPTION HOR. MSRW
Message indicating that the option has been installed. There is no selection and the next selection is printed after
this title. If the hor. magn. / MICR option is present, "+ MICR" is shown beside "MSRW".
Parameter
STANDARD
If the IBM 3604 STANDARD has been configured
Parameter
END-SENTINEL
DISPLACEMENT
DUPLICATE:
DOUBLE FIELD
RETRY
STRIPE HANDLING
4-16
Values possible
DIN/ISO
ANSI
IBM 3604 *
Values possible
C *
F
STANDARD *
+10
+ 20
N *
Y
N *
Y
3
1
NORMAL
FAST
Service Manual
Description
Sets the magnetic standard.
See
page 4-17
See
page 4-17
See
page 4-16
Description
Sets the closing code.
Sets the position of the magnetic stripe.
Sets or not duplication of the field.
Sets or not control on the two fields recorded.
Sets read retries.
Permits fast or normal management of the magnetic
stripe. In the case of normal management, each time
the magnetic stripe is read or written, passbook width is
measured in order to establish the precise position of
the stripe.
In fast management, the width of the passbook is
measured once only with the procedure described in
the specific chapter and no measurements are made
during reading or writing of the stripe, thus increasing
speed of management of the stripe.
XZAC4219-05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr2 plus

Table of Contents