If the ANSI or DIN/ISO STANDARD has been configured
Parameter
DISPLACEMENT
DUPLICATE:
DOUBLE FIELD
RETRY
STRIPE HANDLING
XZAC4219-05
Values possible
STANDARD *
+10
+ 20
N *
Y
N *
Y
3
1
NORMAL
FAST
Service Manual
Description
Sets the position of the magnetic stripe.
Sets or not duplication of the field.
Sets or not control on the two fields recorded.
Sets read retries.
Permits fast or normal management of the magnetic
stripe. In the case of normal management, each time
the magnetic stripe is read or written, passbook width is
measured in order to establish the precise position of
the stripe.
In fast management, the width of the passbook is
measured once only with the procedure described in
the specific chapter and no measurements are made
during reading or writing of the stripe, thus increasing
speed of management of the stripe.