Console LED
ON
Ready
Station1
O
X
-
O
X
O
O
X
X
O
X
X
O
X
X
O
X
-
O
O
O
5-6
Anomalies
Local
Station 2
FPGA scanner
X
-
error
HW Setup - On
the display (if
present) appears
the message
«WARNING
Setup
Hardware».
Inconsistency of
X
X
calibration values
(photosensors,
alignments etc).
All the calibration
values are
initialised with
their default
values.
-
-
Carriage motor
Scanner STATIC
-
X
RAM error
Scanner
X
-
DYNAMIC RAM
error
Perform the
scanner
calibration - On
the display (if
X
X
present) the
message
appears «Make
SCANNER
Calibration».
PTC power unit
-
O
not working
Service Manual
Possible solution
•
Perform calibration of the
scanner. See the section
"Calibrating the scanner" on
page 4 - 28.
•
Replace the motherboard. See
the section
Disassembling/
reassembling the motherboard
(printers with scanner).
•
Press any key on the console to
display the next anomaly, when
necessary.
•
Perform all the printer
calibrations. See the section
"PROGRAMMING AND
CALIBRATION" on page 4 - 1.
•
Replace the motherboard. See
the section
Disassembling/
reassembling the motherboard
(printers with scanner)
Disassembling/reassembling
the motherboard (printers with
serial number 8.xxx.xxx and
1.xxx.xxx).
See the section
"Faults during
writing of the document" on page 5 -
17.
Replace the motherboard. See the
section
Disassembling/
reassembling the motherboard
(printers with scanner).
Replace the motherboard. See the
section
Disassembling/
reassembling the motherboard
(printers with scanner).
•
Press any key on the console to
display the next anomaly, when
necessary.
•
Perform calibration of the
scanner. See the section
"Calibrating the scanner" on
page 4 - 28.
Replace the power unit. See the
section
"Power supply unit
disassembly/reassembly" on page 7
-
26.
or