ARMATURE COIL
Using the pocket tester, check the coil for open and
ground by placing probe pins on each commutator seg-
ment and rotor core (to test for ground)and on any two
segments at various places (to test for open), with the
brushes lifted off the commutator surface.
If the coil is found to be open-circuited or grounded,
replace the armature. Continuous use of a defective
armature will cause the starting motor to suddenly fail.
Pocket tester : 09900 - 25002

STARTER RELAY INSPECTION

● Disconnect the starter relay lead wire coupler.
Check the coil for "open" , "ground"and ohmic resis-
tance. The coil is in good condition, if the resistance
is as follows.
Pocket tester : 09900 - 25002
Starter relay standard resistance
0 ~ 70 Ϊ
ELECTRICAL SYSTEM 5-6