NO-LOAD PERFORMANCE OF A.C. GENERATOR
● Disconnect the magneto lead wire coupler.
● Start the engine and keep it running at 5,000 rpm.
● Using a pocket tester, measure the AC voltage
between the three lead wire. If the tester reading is as
follows, magneto is in good condition.
Standard no - load performance
of A.C. generator

REGULATOR/RECTIFIER

● Disconnect the coupler.
● Using the pocket tester(×1㏀ Range), measure the
resistance between the terminals as shown in the fol-
lowing table. If the resistance checked is incorrect,
replace the regulator/rectifier.
Pocket tester : 09900 - 25002
1
1
1
2
50 ~ 230
3
4

STARTER SYSTEM

The starter system is shown in the diagram below: namely, the starting motor, starter relay, starter switch and battery.
Depressing the starter switch (on the right handlebar switch box) while squeezing the front or rear brake lever energizes
the relay, causing the contact points to close which connects the starting motor to the battery.
Battery
More than 17 V (at 5,000 rpm)
� Probe of tester to:
2
3
2
3
50 ~ 260
10 ~ 100
Fuse
IG switch
Starter switch
Brake switch
Unit : ㏀
4
4
Starter relay
R
Y/G