5-13 ELECTRICAL SYSTEM
● Using the pocket tester, measure the battery voltage.
The tester should indicate more than 12.5-12.6
V(DC)as shown in the Fig. If the battery voltage is
lower than the specification, charge the battery with a
battery charger.
NOTE:
Initial charging for a new battery is recommended if two
years have elapsed since the date of manufacture.
CAUTION OF BATTERY TREATMENT
The battery is needed attention generally as occur flammability gas.
If does not, it should be explosion and severe accident.
Pay attention to the following points.
● Prohibit positively that come in contact with short, spark or firearms.
● The battery recharge where be well-ventilated wide place.
Prohibit positively at the shut tight room.

RECHARGING OPERATION

● Using the pocket tester, check the battery voltage. If
the voltage reading is less than 12.0V(DC), recharge
the battery with a battery charger.
● When recharging the battery, remove the battery
from the motorcycle.
● Do the battery by standard charging usually.
BATTERY CHARGING CURRENT
Standard
Fast
● After recharging, wait for more than 30 minutes and
check the battery voltage with a pocket tester.
● If the battery voltage is less than 12.0V, recharge the
battery again.
● If the battery voltage is still less than 12.0V after
recharging, replace the battery with a new one.
NOTE:
When a battery is left for a long term without using, it is
subject to discharge. When the motorcycle is not used
for more than 1 month(especially during the winter sea-
son), recharge the battery once a month at least.
WARNING
∙Charging equipment of this motorcycle is
designed for the MF(Maintenance Free) battery.
∙No use except the specificated battery.
0.4A × 5~10 Hours
4A × 30 Minutes
(at 25℃)
seconds
Time
Time
(at 0~40℃)
Battery charged condition
(Minutes)
(Minutes)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents