Stator Coils - HYOSUNG Prima Service Manual

Hide thumbs Also See for Prima:
Table of Contents

Advertisement

5-3 ELECTRICAL SYSTEM
● Check the ignition coil with the pocket tester.
Pocket tester : 09900 - 25002
Ignition coil resistance
Primary
Secondary
C.D.I. UNIT
● Using the pocket tester (R 1
resistance between the lead wire in the following table.
Pocket tester : 09900 - 25002
� � Probe of tester to :
B/Y
W/BL
B/Y
W/BL
14~18
B/R
3~5
B/W
7~11
W
12~16
Br
10~14

STATOR COILS

● Using the pocket tester, measure the resistance
between the lead wire and ground. If the resistance
checked is incorrect, replace the coil.
Stator coil resistance
Lead wire of tester
� (Red)
� (Black)
Y/W
Ground
W/R
Ground
B/R
Ground
Br
W
CHARGING OUTPUT CHECK
Start the engine and keep it running at 5,000 rpm with lighting
switch turned " ON " .
Measure the DC voltage between the battery terminal � and �
with a pocket tester.
If the tester reads under or over following specification, check
the no-lead performance or replace the regulator/rectifier.
CAUTION
When making this test, be sure that the battery is
in fully-charged condition.
Pocket tester : 09900 - 25002
Engine tachometer : 09900 - 26006
Standard charging output
0.19 ~ 0.24 Ϊ
5.4 ~ 6.6 ㏀
range), measure the
Unit : ㏀
B/R
B/W
W
7~10
3~4
7~10
3~4.5
3~4.5
6~8
25~35
5~7
1.2~2.5
5~8
Unit : Ϊ
Standard resistance
0.54 ~ 0.80 Ϊ
Lighting coil
0.69 ~ 1.03 Ϊ
Charging coil
220 ~ 260 Ϊ
Exciting coil
90 ~ 110 Ϊ
Pick-up coil
13.0 ~ 16.0 V (at 5,000 rpm)
Br
5~7
1.2~2.5
27~37
B/R
Ground
Plug cap
B/Y
W/BL
B/R
B/W
W
Br

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents