[7] Communication test
Use the following procedure to perform a communication test.
1.
Select "7: COMMUNICATION" at the TEST menu and then press the
ENT key.
The TEST COMMUNICATION screen shown on the right displays.
"1: OPTICAL":
Refer to the following section for details of the above items.
Press the BS/C key to return to the TEST menu.
Infrared Communication Test
1.
Arrange two BHTs, one as a master station and the other as a slave station (to be tested) with
their IrDA interface ports facing each other as illustrated below.
This test involves transmitting data from the test BHT and the master BHT returning the data to the test
BHT.
Master BHT
2.
Select "1: OPTICAL" at the TEST COMMUNICATION menu and
then press the ENT key.
The TEST COMMUNICATION screen displays as shown on the right.
Performs an infrared communication test.
Data
Max. 15 cm
2D Code Handy Terminal
Slave BHT
(to be tested)
133