HP AlphaServer TS15 Owner's Manual page 206

Servers
Table of Contents

Advertisement

The elements of the sample dial string and alert string are shown in Table 6–3. Paging
services vary, so you need to become familiar with the options provided by the paging
service you will be using. The RMC supports only numeric messages.
Sets the string to be used by the RMC to dial out when an alert condition occurs.
The dial string must include the appropriate modem commands to dial the number.
Sets the alert string, typically the phone number of the modem connected to the
remote system. The alert string is appended after the dial string, and the combined
string is sent to the modem when an alert condition is detected.
Enables remote access to the RMC's modem port.
Clears the current alert condition.
Enables the RMC to page a remote system operator.
Forces an alert condition. This command is used to test the setup of the dial-out
alert function. It should be issued from the local serial terminal or local VGA
monitor. As long as no one connects to the modem and there is no other alert
pending, this alert will be sent to the pager as soon as the modem is connected to the
system. If the pager does not receive the alert, re-check your setup.
Status of the RMC configuration.
NOTE: If you do not want dial-out paging enabled at this time, enter the disable alert
command after you have tested the dial-out alert function. Alerts continue to be
logged, but no paging occurs.
6-28
hp AlphaServer TS15 Owner's Guide

Advertisement

Table of Contents
loading

Table of Contents