HP AlphaServer TS15 Owner's Manual page 202

Servers
Table of Contents

Advertisement

Dialing In
This example shows the screen output when a modem connection is established.
ATDT915085553333
CONNECT 9600/ARQ/V34/LAPM
RMC Password: *****
Welcome to RMC V1.1-0
>>>
>>>
hp AlphaServer TS15 Remote Management Controller - Revision V1.1-0
RMC> status
RMC Runtime Firmware Revision: V1.1-0
RMC Booter Firmware Revision: V1.1-0
System Power: ON
System Halt: Deasserted
Escape Sequence: ^[^[RMC
Remote Access: Enabled
Modem RMC Defaults: Disabled
RMC Password: Set
Alerts: Disabled
Alert Pending: NO
Latest Alert: AC Loss
Init String: AT&H2E0&C1&D0S0=2
Dial String: ATD915085554444
Alert String: ,,,,,,,,,,5551234
User String:
Com1 Baud:9600
Flow:SOFTWARE
Logout Timer: 20 minutes
Voltage Status: OK
Thermal Status: OK
Warning Threshold:
Fan Status: OK
PCI Riser: Installed
POST DPR: OK
NVRAM: OK
Watchdog Timer: Disabled
RMC> hangup
+++
NO CARRIER
In the preceding example, enter commands at the RMC prompt to monitor and control the
remote system.
When you have finished a modem session, enter the hangup command to cleanly terminate
the session and disconnect from the server.
Unsetting the password
If the password is forgotten, you can reset it by using the set password command.
4. Enter the set password command at the RMC prompt.
6-24
hp AlphaServer TS15 Owner's Guide
hp AlphaServer TS15 Platform Status
Status: Initialized
Warning Alerts: Disabled
Mode:THROUGH
Thermal Shutdown: Enabled
60.00°C
Fatal/Power-Down Threshold:
Fan Shutdown: Enabled
GPIOs: OK
Watchdog Reboot: Disabled
Modem:DISABLED
Rmc:ENABLED
LM75: OK
65.00°C

Advertisement