Field
Alert Pending
Latest Alert
Init String
Dial String
Alert String
User String
COM1
Logout Timer
Voltage Status
Thermal Status
Meaning
Alert pending status:
YES = Alert condition is awaiting delivery.
NO = No alert condition is awaiting delivery.
Text string that describes the last alert generated on the system.
Initialization string that was set for modem.
Dial string that is sent to modem when an alert occurs
Identification string to be sent to pager when an alert occurs.
Usually set to phone number of alerting system.
System notes supplied by the user.
State of the system's COM1 settings:
COM1_BAUD:
1800, 2000, 2400, 3600, 4800, 7200, 9600, 19200,
38400, 57600
COM1_FLOW:
NONE, SOFTWARE, HARDWARE, BOTH
COM1_MODE:
THROUGH, SNOOP, SOFT_BYPASS, FIRM_BYPASS
COM1_MODEM:
ENABLED, DISABLED
COM1_RMC:
ENABLED, DISABLED
The amount of time before the RMC terminates an inactive
modem connection (in minutes).
Current state of system power:
OK = All power is good
FAIL = One or more of the system voltages has crossed
fatal threshold
System thermal status:
OK = Thermal status is good
WARNING = Thermal warning threshold has been crossed
(fatal threshold has not been crossed)
FAIL = Thermal fatal threshold has been crossed
Using the Remote Management Console