Replacing Middle Drive – Internal Storage Cage
1. Shut down the system and remove the top cover as explained in Section 4.2.
2. Remove the internal storage cage
3. Remove the four screws
assembly
from the storage cage.
4. Remove the four screws
out. Set the drive aside.
5. Insert the new drive into the drive assembly and fasten the four bottom screws.
6. Slide the drive assembly into the storage cage and fasten the four side screws.
7. Reinstall the storage cage as explained in Section 4.8.
8. Replace the top cover and reassemble the system enclosure as explained in the end of
Section 4.2.
9. Turn on system power by pressing the power switch on the operator control panel. Boot
the operating system.
Verification
Enter the SRM and use the init and show device commands to verify that the system has
identified the new drive.