6-8 List of Modbus Communication (Modbus-RTU) Data
Register
No.
1466h
1467h
1468h
1469h
146Ah Reset Selection
146Bh Reset Restart Selection
146Ch
146Dh MP Gain Setting
6
146Eh AM Gain Adjustment
146Fh
to
1470h
1471h AM Bias Setting
1472h Reserved
1473h
1474h
to
1485h
1486h
1487h
1488h
1489h
148Ah
to
148F
1490h
1491h
6-61
Parameter
Function name
Co-inverter
Communication Starting
Station Number
Co-inverter
Communication Ending
Station Number
Co-inverter
Communication Starting
Selection
UP/DWN Storage
Selection
UP/DWN Clear Terminal
Mode
Reserved
Overload 1 Warning
Level 2
Reserved
Output P1/EDM ON
Delay Time
Output P1/EDM OFF
Delay Time
Output P2 ON Delay
Time
Output P2 OFF Delay
Time
Reserved
Output RY ON Delay
Time
Output RY OFF Delay
Time
Monitor and setting
R/W
No.
parameters
C098
R/W 1 to 8
C099
R/W 1 to 8
00: 485 terminal
C100
R/W
01: Always started
00: Do not store frequency
C101
R/W
data
01: Store frequency data
00: Trip reset at power-on
01: Trip reset at power-off
02: Enabled only during trip
C102
R/W
(Reset when the power
is ON.)
03: Trip reset only
00: 0 Hz restart
01: Frequency matching
C103
R/W
restart
02: Frequency pull-in restart
00: 0 Hz
C104
R/W
01: EEPROM data at
power-on
C105
R/W 50 to 200
C106
R/W 50 to 200
−
−
−
C109
R/W 0 to 100
−
−
−
C111
R/W 0 to 20000
−
−
−
C130
R/W 0 to 1000
C131
R/W 0 to 1000
C132
R/W 0 to 1000
C133
R/W 0 to 1000
−
−
−
C140
R/W 0 to 1000
C141
R/W 0 to 1000
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Data
Page
resolution
−
−
6-22
−
−
5-71
−
5-100
−
−
5-71
1 [%]
5-43
1 [%]
5-45
−
−
1 [%]
5-45
−
−
0.01 [%]
5-115
−
−
0.1 [s]
0.1 [s]
5-36
0.1 [s]
0.1 [s]
5-36
−
−
0.1 [s]
5-36
0.1 [s]