Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Describes the details of each parameter.
5-1
Monitor Mode ........................................................................ 5-1
Output Frequency Monitor [d001] ................................................... 5-1
Output Current Monitor [d002] ........................................................ 5-1
Rotation Direction Monitor [d003] ................................................... 5-2
PID Feedback Value Monitor [d004] ............................................... 5-2
Multi-function Input Monitor [d005].................................................. 5-3
Multi-function Output Monitor [d006]............................................... 5-3
Real Frequency Monitor [d008]....................................................... 5-5
Torque Reference Monitor [d009] ................................................... 5-5
Torque Bias Monitor [d010]............................................................. 5-6
Output Torque Monitor [d012]......................................................... 5-6
Output Voltage Monitor [d013] ........................................................ 5-6
Input Power Monitor [d014]............................................................. 5-7
Integrated Power Monitor [d015]..................................................... 5-7
Total RUN Time [d016] ................................................................... 5-8
Power ON Time [d017] ................................................................... 5-8
Fin Temperature Monitor [d018] ..................................................... 5-8
Life Assessment Monitor [d022]...................................................... 5-9
Position Command Monitor [d029].................................................. 5-9
Current Position Monitor [d030] ...................................................... 5-9
User Selection Monitor (2 Types) [d050] ...................................... 5-10
Inverter Mode Monitor [d060]........................................................ 5-10
Fault Counter [d080] ..................................................................... 5-11
Fault Monitors 1 to 6 [d081 to 086] ............................................... 5-11
Warning Monitor [d090]................................................................. 5-11
DC Voltage Monitor [d102]............................................................ 5-12
Regenerative Braking Load Rate Monitor [d103].......................... 5-12
Electronic Thermal Load Rate Monitor [d104] .............................. 5-12
5-2
Basic Functions .................................................................. 5-13
Heavy Load/Light Load Selection ................................................. 5-13
RUN Command Selection............................................................. 5-22
RUN Direction Selection ............................................................... 5-23
Rotation Direction Limit Selection ................................................. 5-23
Stop Selection............................................................................... 5-24
Acceleration/Deceleration Time .................................................... 5-24
Base Frequency............................................................................ 5-26
AVR Function................................................................................ 5-27
Maximum Frequency .................................................................... 5-28
5-3
Input/Output Terminals ...................................................... 5-29
Multi-function Input Selection........................................................ 5-29
Multi-function Input Operation Selection ....................................... 5-31
5