Monitor Mode; Output Frequency Monitor [D001]; Output Current Monitor [D002] - Omron 3G3MX2 User Manual

Sysdrive mx2 series multi-function compact inverter
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

5-1 Monitor Mode

5-1 Monitor Mode

The following explains the Inverter's display functions such as the output frequency monitor
and fault monitor.

Output Frequency Monitor [d001]

Displays the output frequency of the Inverter. During stop, "0.00" is displayed.
The monitor LED indicator "Hz" is lit while the d001setting is displayed.
Parameter
d001
b163
5
If Frequency Reference Selection is set to Digital Operator (A001 = 02), enabling d001/d007
Frequency Setting Mode Selection (b163 = 01) lets you change the Output Frequency Monitor
(d001) setting using the Increment/Decrement keys only during operation.
Changed Output Frequency Monitor (d001) will be reflected to the Output Frequency Setting
(F001). Pressing the Enter key stores the setting in the EEPROM.
Since F001 is rewritten while d001 is still displayed, there may be a time gap between the key
operation and display change depending on the acceleration/deceleration time.
While the PID function is activated or being stopped, the output frequency cannot be changed.
The frequency cannot be changed in the individual input mode by pressing the Increment/
Decrement keys simultaneously.

Output Current Monitor [d002]

Displays the output current value of the Inverter. During stop, "0.0" is displayed.
The monitor LED indicator "A" is lit while the d002 setting is displayed.
Parameter
d002
5-1
Function name
No.
Output Frequency
Monitor
d001/d007
Frequency Setting
Mode Selection
Related functions
Reference
Function name
No.
Output Current
Monitor
Data
0.00 to 400.0
0.00 to 1000.
High-frequency mode
00: Disabled
(The output frequency cannot be
changed using d001/d007.)
01: Enabled
(The output frequency can be
changed using d001/d007.)
A001, F001
Data
0.0 to 655.3
The minimum unit varies depending on
the capacity.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Default
Unit
setting
Hz
00
Default
Unit
setting
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents