5-9 Functions Relating to Protections, Warnings and Various Output Signals
Output current
Maximum frequency
A004/A204
Inverter output
frequency

Overload Warning

If the applied load is large, the Inverter can output an overload warning signal before an
overload trip occurs.
This helps prevent mechanical damage due to an overload in the carrier machine, or an
operation line stop due to overload protection of the Inverter.
Allocate "03: OL (Overload warning)" or "26: OL2 (Overload warning 2)" to any Multi-function
Output Terminal Selections (C021 to C022) or Multi-function Relay Output Function Selection
(C026). (Two types of overload warning signals can be output.)
5
Parameter
C041/C241
C021 to C022
Overload limit level
Overload warning level
Output current
OL/OL2 output
5-115
Overload warning level
b022/b025
b222
b023/b026/b223
Function name
No.
Overload Warning
C040
Signal Output
Mode Selection
Overload Warning
Level 1/2
Overload 1
C111
Warning Level 2
Multi-function Output
Terminal Selection
Multi-function
C026
Relay Output
Function Selection
b022/b025
C041/C111
Deceleration set by the
overload limit parameter
Data
00: Enabled in acceleration/deceleration
and constant speed operation
01: Enabled in constant speed operation
0.0
The Inverter does not operate.
0.0 to 2.0 × Rated current
Outputs an OL signal when the
overload warning level is reached.
0.0
The Inverter does not operate.
0.0 to 2.0 × Rated current
Outputs an OL2 signal when the
overload warning level is reached.
03: OL (Overload warning)
26: OL2 (Overload warning 2)
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Target frequency
F001
Default
Unit
setting
01
Rated
current
A
× 1.15
Rated
current
A
× 1.15