Fault Counter [D080]; Fault Monitors 1 To 6 [D081 To 086]; Warning Monitor [D090] - Omron 3G3MX2 User Manual

Sysdrive mx2 series multi-function compact inverter
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

5-1 Monitor Mode

Fault Counter [d080]

Displays the number of times the Inverter has tripped.
This number is saved in the EEPROM when the power is turned off.
Parameter
d080

Fault Monitors 1 to 6 [d081 to 086]

Displays the records of the last 6 errors. Error records are saved in the EEPROM when the
power is turned off.
The record of the latest error is displayed under Fault Monitor 1 (d081).
(Display)
(1) Cause of trip (One of E01 to E83 is displayed.)
5
(2) Output frequency [Hz] at the time of tripping
(3) Output current [A] at the time of tripping
(4) P-N DC voltage [V] in the main circuit at the time of tripping
(5) Total Inverter RUN time [h] before the trip
(6) Total Inverter power ON time [h] before the trip
dk0k8k1
_k_k_k_

Warning Monitor [d090]

If the set data is inconsistent with other data, a warning is displayed.
While a warning is present, the Program LED (PRG) indicator remains lit until the data is
corrected.
For details on the Warning display, refer to "Warning Display" on page 7-7.
5-11
Function name
No.
Fault Counter
Refer to "Inverter Fault Factor List" on page 6-35.
If the Inverter is currently stopped (E**.1), the monitor value may become zero.
If tripping occurs due to ground fault at power-on, the monitor value may become zero.
(1) Trip factor
ek0k7.2
is shown if no trip has occurred.
Data
0. to 9999.
1,000 to 6,553 (Displayed in increments
of 10.)
(2) Frequency
(3) Current
(4) DC voltage
6k0.0k0
4.0k0
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Default
setting
(5) Total
(6) Total
RUN time
ON time
4k0k0.2
1k5.
Unit
Time
1k8.