FF1: System Programming
Introduction
FF1 8: Digital Pad Settings
0
System
Configuration
Digital Pad Settings for Extension Pad Class
(all CPCs) - Version 1.0 or higher
FF1
Set volume adjustments for phone connections between Extension Pad
Classes 1-8 (the transmitting end of the connection) and 30 other pad classes
System
(the receiving end of the connection).
FF2
Trunks
0001-0030=transmitted by Extension Pad Class 1
0031-0060=transmitted by Extension Pad Class 2
FF3
0061-0090=transmitted by Extension Pad Class 3
Extensions
0091-0120=transmitted by Extension Pad Class 4
0121-0150=transmitted by Extension Pad Class 5
0151-0180=transmitted by Extension Pad Class 6
0181-0210=transmitted by Extension Pad Class 7
FF4
0211-0240=transmitted by Extension Pad Class 8
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
Notes:
Adjust the default setting(s) in this address whenever other parties have difficulty hearing a particular
FF7
extension, or the extension user sounds too loud during conversations. Extension Pad Classes 1-8 can
Applications
be assigned to individual extensions in FF3.
The default settings in this address are intended for different phone types as follows:
Extension Pad Class 1: for SLT
FF8
Extension Pad Class 2: for SLT/loss compensation
Extension Pad Class 3: for Digital Key Phones
Maintenance
Extension Pad Class 4: for Wireless
Extension Pad Class 5: for ISDN S-point
Extension Pad Class 6: for VM Playback
Extension Pad Class 7: for Attendant
Extension Pad Class 8: for Terminal Adapter
Related Programming:
Appendix A
Extension Digital Pad Class Assignment (pg. 3-26) for dig.&SLT extensions FF3 0 BSSC 08 Hold (1-8) Hold
Extension Digital Pad Class Assignment (pg. 3-39) for ISDN extensions
Appendix B
Page 1-176
FF1 8 01 (0001-0240) Hold (0-31) Hold
(see table, next page)
DBS 576 (USA) issued 05/20/98
Section 400-Programming

*5 *5
Volume Adjustment Setting:
16= 0 dB
0= 0 dB
1= −2 dB
17= +2 dB
2= −4 dB
18= +4 dB
3= −6 dB
19= +6 dB
4= −8 dB
20= +8 dB
5= −10 dB
21= +10 dB
6= −12 dB
22= +12 dB
7= −14 dB
23= +14 dB
8= −16 dB
24= +16 dB
9= −18 dB
25= +18 dB
10= −20 dB
26= +20 dB
11= −22 dB
27= +22 dB
12= −24 dB
28= +24 dB
13= −26 dB
29= +26 dB
14= −28 dB
30= +28 dB
15= −30 dB
31= +30 dB
FF3 1 BSSC 07 0 Hold (1-8) Hold
Introduction
0
System
Configuration
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B
576-13-400

Advertisement

Table of Contents
loading

Table of Contents