2.2

Develop Roller Counter Reset Function

This function is to manually perform the operation same as the one when a toner cartridge is
replaced with a new one. The purpose of this function is to provide a means to resolve an error
when a new toner cannot be recognized by the product, and the LCD display fails to be cleared.
<Operating procedure>
Note:
- If there is no operation for 30 seconds or more, the machine automatically returns to step (1).
- While starter toner is also displayed on the LCD, make sure to select standard toner.
(1) Press the Clear/Back button while the top cover is being
opened.
(2) "K. TNR-STD" appears on the LCD.
Press the
or
cartridge, and then press the OK button.
LCD
K.TNR-STD
K.TNR-STR
C.TNR-STD
C.TNR-STR
M.TNR-STD
M.TNR-STR
Y.TNR-STD
Y.TNR-STR
(3) The "K. TNR-STD/1. Reset 2.Exit" will appear on the
LCD. If resetting the counter, press the 1 button. If not,
press the 2 button.
(4) The develop roller counter is reset.
(5) The machine returns to the state in which the top cover is
open.
7-58
button to select the appropriate toner
Description
Reset the develop roller counter of
standard black toner cartridge.
Reset the develop roller counter of
starter black toner cartridge.
Reset the develop roller counter of
standard cyan toner cartridge.
Reset the develop roller counter of
starter cyan toner cartridge.
Reset the develop roller counter of
standard magenta toner cartridge.
Reset the develop roller counter of
starter magenta toner cartridge.
Reset the develop roller counter of
standard yellow toner cartridge.
Reset the develop roller counter of
starter yellow toner cartridge.