Color fax/mfc
Hide thumbs Also See for DCP-9010CN:
Table of Contents

Advertisement

WSW60 (Function setting 25)
Selector No.
1
l
Not used.
3
4
Caller ID primary closed circuit timing
adjustment
5
Output of CNG detection result to the
6
activity report
7
Delay time which allows a polarity
l
inversion interrupt from polarity
8
inversion judgment
- Selector 6: Output of CNG detection result to the activity report
Setting this selector to "1" (Enable) changes the items to be listed in the activity report as follows.
FAX No./NAME
DURATION
PAGE (S)
RESULT
Function
CNG DETECTION STATE
(Tone detection status, calling/called status)
RCV MODE
(FAX receive mode setting)
EASY RCV
(Easy receive setting)
TRIGGER
(FAX receive trigger)
App.1-48
Setting and Specifications
No. 4 5
0 0: OFF
0 1: Fast
1 0: Normal
1 1: Slow
0: Disable (default)
1: Enable
No. 7 8
0 0: 500 ms
0 1: 750 ms
1 0: 1,000 ms
1 1: 1,500 ms