WSW04 (Transfer facility setting)
Selector No.
Earth function in transfer facility
1
(Not used.)
2
Dual tone detection frequency in ICM
recording (Not used.)
3
Dual tone detection sensitivity in ICM
4
recording (Not used.)
Length of time added to time
designated by selectors 3 and 4 on
5
the WSW 24 (time between CML ON
and pseudo ring backtone return).
6
l
Break time length for flash function
8
Note:
Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is
supported.
- Selectors 6 through 8: Break time length for flash function
These selectors set the break time length. This setting is effective only when the flash function is
selected for the
One Touch
Function
button by using the function switch.
App.1-7
Setting and Specifications
0: Not added
1: +4 seconds added
No. 6 7 8
0 0 0: 80 ms
0 0 1: 100 ms
0 1 0: 110 ms
0 1 1: 120 ms
1 0 0: 200 ms
1 0 1: 250 ms
1 1 0: 500 ms
1 1 1: 700 ms