3.7 Unique Switch Adjustment

3.7.1 Setting the Unique Switches

These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power is lost.
1. From standby, press Program key, *, 4.
Set Uniq Switch
2. Press ENTER.
a0:
3. Select the desired unique switch by pressing a one-touch key plus a number on the keypad. For example,
to access parameter B:1, press one-touch "B" plus the number "1" on the numeric keypad.
b1:
4. Press ENTER.
Set Uniq Switch
b1
Bit No.
(The bits are numbered 7 through 0 --- bit 7 is left most.)
5. To navigate through the unique switch settings:
Press
key to move the cursor to the left.
Press
key to move the cursor to the right.
Press the 0 or 1 on the numeric keypad to change the bit value.
Press ENTER to save the setting of the displayed unique switch and advance to the next unique
switch.
(Continue pressing ENTER until the desired unique switch is shown in the display. Be sure to press
ENTER after each unique switch is programmed to save the new setting.)
Press STOP to return the unit to standby.
Note: You can confirm the initial setting of each Unique Switch by the Unique Switches List.
The Unique Switches List will be printed by pressing Program key, *, A(01).

Clearing the Unique Switches

Resets the unique switches to factory defaults.
1. From standby, press Program key, *, 4,
Clear Uniq Switch
2. Press ENTER.
Clear Uniq Switch
Check
Enter/Cancel
3. Press ENTER. The unique switches will reset to factory defaults.
Note: To finish the operation without clearing the unique switches, press CANCEL.
/
/Enter
01100001
/
/Enter
00000000
/
/Enter
00000000
76543210
.
/
/Enter
3-40