3.20 Life monitor maintenance

When you replace the main control PCB, you should register the previous several counter values of the life
monitor.
1. Before updating the software or replacing the main control PCB, you must write down the counter values of
the life monitor.
2. To confirm the life monitor, press Program key, *, 9, ENTER. Then press one-touch key G to P. (See
"3.10.1 Life Monitor," page 3-64.)
3. After you write down the counter values of the life monitor, update the software or replace the main control
PCB.
4. Then, press Program key, *, K(11).
Drum Replaced Count
0000000000
5. Enter previous value of the number of drum replaced time, then press ENTER.
Drum Life
0000000000
6. Enter previous value of the total pages printed on current drum, then press ENTER.
Toner Replaced Count
0000000000
7. Enter previous value of the toner replaced count, then press ENTER.
Toner Life
0000000000
8. Enter previous value of the toner life, then press ENTER.
Fuser Replaced Count
0000000000
9. Enter previous value of the fuser replaced count, then press ENTER.
Fuser Life
0000000000
10. Enter previous value of the fuser life, then press ENTER.
Transfer Rplcd Count
0000000000
11. Enter previous value of the transfer replaced count, then press ENTER.
Transfer Life
0000000000
12. Enter previous value of the transfer roller life, then press ENTER.
Drum Life Span
0000000000
13. Enter previous value of the drum operation time, then press ENTER.
Machine Life
0000000000
14. Enter previous value of the printer operation time, then press ENTER.
15. The machine returns to its standby mode.