INVERTER PCB

1. Remove the TOP FRONT COVER and the TOP RIGHT COVER.
2. Remove the FBS glass.
3. Remove two LENS COVER mounting screws, and then remove the LENS COVER.
4. Disconnect two connectors on the INVERTER PCB and remove two INVERTER PCB mounting screws,
then remove the INVERTER PCB.
LAMP
1. Perform the procedure of step 1 through 3 in "INVERTER PCB," see above.
2. Disconnect the connector for the LAMP on the INVERTER PCB.
3. Remove the two Scanner Upper Cover mounting screws, then remove the SCANNER UPPER COVER
and COVER GLASS.
4. Release the two locking tabs, and then remove the LAMP HOLDER.
5. Remove the LAMP.
Lamp holder
Lens cover
Inverter PCB
5-22
Scanner Upper cover
Cover glass
Lamp