Fusing - Muratec MFX-1300 Field Engineering Manual

Facsimile system
Hide thumbs Also See for MFX-1300:
Table of Contents

Advertisement

2.8.6 Fusing

An Overview
The toner image transferred on to the paper is securely fixed.
A heat roller system is used as the fusing system. The toner image is fused by Heater Roller heated by
the Heater Lamp, and securely fixed by the pressure between the Heater roller and Press rollers.
A Thermistor detects and controls the Heater Roller temperature.
The Thermostat functions when the Heater Lamp is not turned OFF even if the Thermistor detects a high
temperature malfunction.
Fusing Temperature Control Circuit
The Thermistor detects the surface temperature of the Heater Roller and inputs that analog voltage into
the Main Control PCB. Corresponding to this data, the Heater Lamp ON/OFF signal is output to the Heater
ON/OFF switch of the power supply unit, causing the Heater Lamp to turn ON or OFF to control the fusing
temperature.
When the Heater Lamp is not turned OFF even if the Thermistor detects a high temperature malfunction,
the thermostat shuts down the power to the heater lamp. When the thermostat is malfunction, the thermal
cut-off shuts down the power to the heater lamp.
AC Inlet
Main switch
N
Power supply unit
Heater
on/off
switch
2-16
Main Control PCB
Fusing temperture
control circuit
Fusing unit
Heater Lamp
Thermostat
Thermal cut-off
Thermistor

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1600Mfx-1700Mfx-1200

Table of Contents