Muratec MFX-1300 Field Engineering Manual page 85

Facsimile system
Hide thumbs Also See for MFX-1300:
Table of Contents

Advertisement

Unique Switch f:2 - Printer
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
LED print head exposure
time adjustment for lists, test
4
0
patterns and PCL printing
3
0
2
0
1 step = 1.74 s
1
0
0
0
Note: This setting effects
after turning the power switch
off/on.
Unique Switch f:3
Unique Switch f:5 - Printer
Initial
Switch
Setting
7
1
Factory use only
6
0
Limit of the memory capacity
in Reverse order print
5
1
4
0
Ignore the size error with
bypass tray
0: No
1: Yes
3
0
Factory use only
2
0
Factory use only
1
0
Factory use only
0
1
Primary copying upon
printing the received data
0: No
1: Yes
Adjust
Initial setting is "000000" and 28.65 sec. If you
want to change the exposure time, set this switch
within the following range.
If you set the time to be shorter, the print density will
be light.
Switch 5 4 3 2 1 0
f:4 --- Factory use only
Adjust
Determine the limit of the memory capacity for
storing the received document in the reverse order
print. If the data reached to this limit during
receiving, the normal order print will start.
Setting to "1", the copying job will interrupt the
printing job of received document.
3-55
Usage/Comments
1 0 0 0 0 0
54.69 sec Darkest
|
1 1 0 0 0 1
25.17 s
1 1 0 0 0 0
26.91 s
1 0 1 1 1 1
28.65 s
1 0 1 1 1 0
30.38 s
1 0 1 1 0 1
32.12 s
|
1 1 1 1 1 1
0.87 s
Usage/Comments
Switch 6 5
0 0
126 KB
0 1
521 KB
1 0
1024 KB
1 1
2048 KB
Lightest

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1600Mfx-1700Mfx-1200

Table of Contents