Muratec MFX-1300 Field Engineering Manual page 87

Facsimile system
Hide thumbs Also See for MFX-1300:
Table of Contents

Advertisement

Unique Switch g:0 - Remote reception
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
Factory use only
2
0
Use numeric keypad on the
fax using second phone
(Only for MFX-1300/1200)
0: No
1: Yes
1
1
Manual transmit/receive
using Start key after off-hook
of second phone
(Only for MFX-1300/1200)
0: No
1: Yes
0
0
Silent detection
0: No
1: Yes
Unique Switch g:1
Unique Switch g:7 – Remote reception and TAD interface
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Strict condition of CNG
detection after OGM output
0: No
1: Yes
4
0
CNG detection during OGM
output in ANS Ready
0: Yes
1: No
3
0
Number of detection DTMF
2
0
1
1
0
1
Adjust
Determines if using the numeric keypad on the
control panel of the fax using the second phone.
Determines if transmitting or receiving manually
using Start key after off-hook of the second phone.
Note: Initial setting for MFX-1700 is "0".
Enables or disables silent detection during Ans/Fax
Ready mode.
g:6 --- Factory use only
Adjust
When set at "1", the condition of CNG detection
becomes strict. CNG should be detected 2times
continuously and the OFF time should be 2 4 sec.
Sets the number of detection the DTMF during
Ans/Fax Ready mode.
Switch 3 2 1 0
3-57
Usage/Comments
Usage/Comments
Number of detection
0 0 0 0
Not detect
0 0 0 1
1
0 0 1 0
2
0 0 1 1
3
Initial setting
0 1 0 0
4
0 1 0 1
5
1 1 1 1
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1600Mfx-1700Mfx-1200

Table of Contents