Monitoring and Managing the Director
88
— 04 Incompatible switch at other end of the ISL.
The switch is configured for Open Fabric mode, and the switch at the
other end of the ISL is an HP switch configured for Homogeneous mode.
— 05 External loopback adapter connected to the
port. A loopback plug is connected to the port, and no diagnostic test is
running.
— 06 N_Port connection not allowed on this port. The
port type configuration does not match the actual port use (the port is
configured as an E_Port, but attaches to a node device).
— Non-HP switch at other end of the ISL. The cable is
connected to a non-HP switch, and Interop mode is set to Homogeneous
mode.
— 08 ISL connection not allowed on this port. The port
type configuration does not match the actual port use (the port is
configured as an F_Port, but attaches to a director or switch).
— 10 Port binding violation—Unauthorized WWN. The
WWN that was entered to configure port binding for this port is not valid,
or a nickname was used that was not configured for the attached device in
the Product Manager.
— 11 Unresponsive node connected to port. Possible causes
are: (1) a hardware problem on a switch or connected node where ELP
frames are not delivered; the response is not received, or a fabric login
(FLOGI) cannot be received (there may be problem in the switch SBAR);
(2) a faulty or dirty cable connection; (3) faulty host bus adapters that do
not send out a FLOGI within a reasonable time frame.
Reason messages for an inactive state include:
— 1 Switch speed conflict (Director 2/64 only). The director data
speed was set to 2 Gb/sec, but the port only supports 1 Gb/sec operation
because it is on an FPM port card. (All ports on all installed FPM cards
will go inactive if the director data speed is set to 2 Gb/sec.) To activate
the port, either set the director data speed to 1 Gb/sec using the Configure
Switch Parameters dialog box, or replace the FPM card with a UPM
card.
— 2 Optics speed conflict (Director 2/64 only). The port data
speed was set to 2 Gb/sec, but the director data speed was set to 1 Gb/sec.
To activate the port, set the director data speed to 2 Gb/sec using the
Configure Switch Parameters dialog box. Note that a port could also be