HP Surestore 64 - Director Switch User Manual page 215

Fw 05.01.00 and sw 07.01.00 - director product manager - user guide
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Table 9: Product Manager Messages (Continued)
Device applications
should be terminated
before starting
diagnostics. Press
NEXT to continue.
[device WWN] cannot
be removed from the
Switch Membership List
while participating in
Switch Binding. The
device must be isolated
from the switch, or
Switch Binding
deactivated before it
can be removed.
Director clock alert
mode must be cleared
before enabling period
synchronization.
Director must be offline
to configure.
Director Product Manager User Guide
Message
Port diagnostics
(loopback tests) cannot
be performed on a
port while an attached
device application is
running.
User attempted to
remove a device
WWN from the Switch
Membership List
(SANtegrity Binding
feature) while Switch
Binding is enabled.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and user is
attempting to enable
Periodic Date/Time
Synchronization
through the Configure
Date and Time dialog
box.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and user is
attempting to enable
Periodic Date/Time
Synchronization
through the Configure
Date and Time dialog
box.
Description
Terminate the device
application and perform
diagnostics again.
Remove the device from the
switch by blocking the port,
setting the switch offline, or
disabling Switch Binding
through the Switch Binding
Change State dialog box before
removing devices from the
Switch Membership List.
Disable clock alert mode
through the Configure FICON
Management Server dialog
box.
Disable clock alert mode
through the Configure FICON
Management Server dialog
box.
Information and Error Messages
Action
215

Advertisement

Table of Contents
loading

This manual is also suitable for:

Director 2/64Director 2/140

Table of Contents