If the server stops during testing and you cannot continue, restart the server and try running the diagnostic
programs again. If the problem remains, replace the component that was being tested when the server
stopped.

Diagnostic text messages

Diagnostic text messages are displayed while the tests are running. A diagnostic text message contains
one of the following results:
Passed: The test was completed without any errors.
Failed: The test detected an error.
User Aborted: You stopped the test before it was completed.
Not Applicable: You attempted to test a device that is not present in the server.
Aborted: The test could not proceed because of the server configuration.
Warning: The test could not be run. There was no failure of the hardware that was being tested, but there
might be a hardware failure elsewhere, or another problem prevented the test from running; for example,
there might be a configuration problem, or the hardware might be missing or is not being recognized.
The result is followed by an error code or other additional information about the error.

Viewing the test log

To view the DSA log when the tests are completed, select Utility from the top of the screen and then select
View Test Log. To view a detailed test log, press Tab while you view the DSA log. The DSA log data
is maintained only while you are running the diagnostic programs. When you exit from the diagnostic
programs, the DSA log is cleared.
To save the DSA log to a file on a diskette or to the hard disk, click Save Log on the diagnostic programs
screen and specify a location and name for the saved log file.
Notes:
1. To create and use a diskette, you must add an optional external diskette drive to the server.
2. To save the test log to a diskette, you must use a diskette that you have formatted yourself; this
function does not work with preformatted diskettes. If the diskette has sufficient space for the test log,
the diskette can contain other data.

Diagnostic messages

The following table describes the messages that the diagnostic programs might generate and suggested
actions to correct the detected problems. Follow the suggested actions in the order in which they are
listed in the column.
82
ThinkServer TD200x Hardware Maintenance Manual