Lenovo ThinkServer TD200x Hardware Maintenance Manual page 38

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823" on page 221 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
Error code
Description
3808000
IMM communication failure
3808002
Error updating system configuration to IMM
3808003
Error retrieving system configuration from
IMM
3808004
IMM system event log full
3818001
Core Root of Trust Measurement (CRTM)
update failed
3818002
Core Root of Trust Measurement (CRTM)
update aborted
3818003
Core Root of Trust Measurement (CRTM)
flash lock failed
3818004
Core Root of Trust Measurement (CRTM)
system error
30
ThinkServer TD200x Hardware Maintenance Manual
Action
1. Remove power from the server for 30 seconds,
and then reconnect the server to power and
restart it.
2. Update the IMM firmware.
3. (Trained service technician only) Replace the
system board.
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup utility and select Save Settings.
3. Update the firmware.
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup utility and select Save Settings.
3. Update the IMM firmware.
• When out-of-band, use the IMM Web interface
or IPMItool to clear the logs from the operating
system.
• When using the local console:
1. Run the Setup utility.
2. Select System Event Logs.
3. Select Clear System Event Log.
4. Restart the server.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.

Advertisement

Table of Contents
loading