Lenovo ThinkServer TD200x Hardware Maintenance Manual page 62

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
LAN: Ethernet[0] interface is now
active.
DHCP setting changed to by user
%1.(%1 = user ID)
IMM: Configuration %1 restored from
a configuration file by user %2.(%1 =
CIM_ConfigurationData.ConfigurationName;
%2 = user ID)
Watchdog %1 Screen Capture
Occurred.(%1 = OS Watchdog or
Loader Watchdog)
Watchdog %1 Failed to Capture
Screen.(%1 = OS Watchdog or
Loader Watchdog)
54
ThinkServer TD200x Hardware Maintenance Manual
Info
The IMM Ethernet interface
has been enabled.
Info
A user has changed the
DHCP mode.
Info
A user has restored the IMM
configuration by importing a
configuration file.
Error
An operating-system error
has occurred, and the screen
capture was successful.
Error
An operating-system error
has occurred, and the screen
capture failed.
No action; information only.
No action; information only.
No action; information only.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface
is enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for
the operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface
is enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for
the operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
6. Update the IMM firmware.
Important: Some cluster
solutions require specific
code levels or coordinated
code updates. If the device
is part of a cluster solution,
verify that the latest level of
code is supported for the
cluster solution before you
update the code.

Advertisement