Installing The 2.5-Inch Disk Drive Cage - Lenovo ThinkServer TD200x Hardware Maintenance Manual

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

1
2.5-inch hard disk drive cage
2
2.5-inch hot-swap drive
To remove the 2.5-inch hard disk drive cage, complete the following steps.
1. Read the safety information that begins on page Safety information..
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
3. Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention: Do not allow the server to fall over.
4. Unlock and remove the left-side cover (see Removing the left-side cover).
5. Remove the power supply or power supplies from the power-supply cage (see Removing a hot-swap
power supply).
6. Rotate the power-supply cage to its open position (see Opening the power-supply cage).
7. Remove the air baffle (see Removing the air baffle).
8. Remove the fan-cage assembly (see "Removing the fan cage assembly" on page 166).
9. Turn the server upright and open the bezel (see Opening the bezel).
10. Remove all of the disk drives from the 2.5-inch disk drive cage (see Removing a 2.5-inch hot-swap
hard disk drive).
11. Disconnect the cables from the 2.5-inch disk drive backplane.
12. Press both drive cage release latches inward; then, pull the drive cage out of the front of server.
13. Remove both of the backplanes from the 2.5-inch disk drive cage (see Removing a 2.5-inch disk
drive backplane).
14. If you are instructed to return the 2.5-inch disk drive cage, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.

Installing the 2.5-inch disk drive cage

.
Chapter 7
Installing optional devices and replacing customer replaceable units
193

Advertisement

Table of Contents
loading

Table of Contents