Ether Downrelay Recovery Mode - Fujitsu XG Series User Manual

Compact, layer 2 switch
Table of Contents

Advertisement

XG Series User's Guide

5.1.1.17 ether downrelay recovery mode

Function
Available Model
Syntax
Options
Use Mode
Explanation
Caution
Default
Set offline state release operation on the Linkdown Relay function of the Ethernet port.
XG0224 / XG0448 / XG2600
ether <number> downrelay recovery mode <mode>
<number>
• The Ethernet port number
Set a port number to use with a decimal value.
When setting multiple port numbers, separate them with commas (,).
When setting sequential numbers, separate them with hyphens (-). (Example: "1-8")
<mode>
Set offline state release operation on the linked port list.
• manual
Specify offline state release with command.
• auto
Specify offline state release with linkup.
Configuration mode (admin class)
Set offline state release operation from the offline port set on the linked port list
information of the Linkdown Relay function.
Setting "manual" for the releasing operation enables the releasing operation of the linked
port by
"online"
command or dynamic definition change.
If the release setting is "auto", the linked ports offline release is possible with the linkdown
relay function setting port's linkup as well as the
definition change.
When the releasing offline operation by linkup is executed when "auto" is set, the system
log is output.
• When the Ethernet port where the Linkdown Relay function is set is in an offline state,
release the offline state with the
state to be linked up.
• Even if the linked port is in an offline state due to something other than the Linkdown
Relay, set the parameters with
when releasing the offline state.
• When the Ethernet port type is a linkaggregation port, and the linked port list
information for the Linkdown Relay function of the linkaggregation is set, the Linkdown
Relay function of the linkaggregation becomes enable and this definition is ignored.
• Even if "auto" is set for release operation, offline state release operation will not be
executed to the ether ports still in a linkup state since some ports are already shifting to
online or offline state.
• Linkdown Relay function operates by ether port or by linkaggregation, but not by
backup port.
For this reason, when the same link operation port is set on an ether or linkaggregation
port in the same backup group, and "auto" is set for offline state release operation, the
release operation may not be executed because the operation is performed by one port
at a time.
It is assumed that "manual" was specified for the linked port list offline state release
operation.
ether <number> downrelay recovery mode manual
"online"
"online"
command, setting "auto" does not change the
"linkaggregation downrelay recovery cause"
107
Chapter 5 Command Reference
command and a dynamic
command
Port Information Settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xg0224Xg0448Xg2600

Table of Contents