Viessmann Vitodens 300 Service Instructions Manual page 81

Type wb3a, 49 and 66 kw gas fired wall mounted condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 300:
Table of Contents

Advertisement

Checking and acknowledging faults
Displayed
Const.
fault code
dd
dE
E4
X
E5
X
E6
X
F0
X
Weat-
System
her-
character-
comp.
istics
X
X
X
Burner
blocked
X
Burner
blocked
X
Burner in
fault state
X
Burner
blocked
Troubleshooting
(cont.)
Cause
Remedy
Room temperature
Check the
sensor heating cir-
room tem-
cuit A1 lead break
perature sen-
sor for
heating cir-
cuit A1
Heating circuit M2
Check the
room temperature
room tem-
sensor lead break
perature sen-
sor for
heating cir-
cuit M2
Fault - supply vol-
Replace con-
tage
trol unit
Internal fault
Check the
ionisation
electrode and
leads. Check
flue gas sys-
tem for
soundness.
Press E.
Flue gas/air supply
Check the
system blocked
flue gas/air
supply sys-
tem. Check
the differen-
tial pressure
sensor.
Press E.
Internal fault
Replace con-
trol unit
81