Viessmann Vitodens 300 Service Instructions Manual page 79

Type wb3a, 49 and 66 kw gas fired wall mounted condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 300:
Table of Contents

Advertisement

Checking and acknowledging faults
Displayed
Const.
fault code
bA
bC
bd
bE
bF
C2
X
C5
X
Weat-
System
her-
character-
comp.
istics
X
Mixer M2
continues
to regulate
X
Control
mode with-
out remote
control
X
Control
mode with-
out remote
control
X
Control
mode
X
Control
mode
X
Control
mode
X
Control
mode,
max. pump
speed
Troubleshooting
(cont.)
Cause
Remedy
Communication
Check the
fault - extension kit
extension kit
for mixer circuit M2
connections
and coding.
Start the
extension kit.
Communication
Check con-
fault - Vitotrol
nections,
remote control
cable, coding
heating circuit A1
address A0
and the
remote con-
trol DIP
switches
Communication
fault - Vitotrol
remote control
heating circuit M2
Vitotrol remote
Check the
control incorrectly
DIP switch
encoded
settings of
the remote
control
Incorrect LON com-
Replace the
munication module
LON commu-
nication mod-
ule
Communication
Check con-
fault - solar control
nections and
unit
coding
address 54
Communication
Check coding
fault - variable
address 30
speed internal
settings;
pump
check the
heating cir-
cuit pump
DIP switch
settings
79