Viessmann Vitodens 300 Service Instructions Manual page 55

Type wb3a, 49 and 66 kw gas fired wall mounted condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 300:
Table of Contents

Advertisement

Code 2
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
A5:5
*
1
With heating circuit
pump logic function
(economy circuit): Heat-
ing circuit pump OFF, if
the outside temperature
(AT) is 1 K higher than
the set room tempera-
ture (RT
AT > RT
Parameter address
A5:...
1
2
3
4
5
6
7
to
15
*1
Only for weather-compensated control units.
Coding
change
Address:
value
A5:0
A5:1
to
A5:15
)
Set
+1 K
Set
With heating circuit pump logic function: Heating
circuit pump OFF, if
AT > RT
+5 K
Set
AT > RT
+4 K
Set
AT > RT
+3 K
Set
AT > RT
+2 K
Set
AT > RT
+1 K
Set
AT > RT
Set
AT > RT
-1 K
Set
AT > RT
- 9 K
Set
Coding
Possible change
Without heating circuit
pump logic function
With heating circuit pump
logic function: Heating
circuit pump OFF, if (see
the following table)