  • Page 1: Service Instructions

    VIESMANN Service instructions for contractors Vitocell 300-B Type EVB DHW cylinders, 300 and 500 litres Vitocell 300-V Type EVI DHW cylinders, 200 to 500 litres VITOCELL 300-B VITOCELL 300-V Please keep safe. 5692 709 GB 3/2007...
  • Page 2: Safety Instructions

    Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained & the Code of Practice of relevant trade associations, Danger & all current safety regulations as This symbol warns against the defined by DIN, EN, DVGW, TRGI, risk of injury.
  • Page 3 Instal- charge static loads. ling non-authorised compo- nents and non-approved modifications/conversion can compromise safety and may invalidate our warranty. For replacements, use only ori- ginal spare parts from Viessmann or those which are approved by Viessmann.
  • Page 4: Table Of Contents

    Further details regarding the individual steps ..........Parts lists Parts list Vitocell 300-B (300 litres).............. Parts list Vitocell 300-B (500 litres).............. 11 Parts list Vitocell 300-V (200 and 300 litres) ..........13 Parts list Vitocell 300-V (500 litres).............. 15 Commissioning/service reports ............... 17 Product parameters ..................
  • Page 5: Commissioning, Inspection, Maintenance

    Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance For further information regarding the individual steps, see the page indicated Commissioning steps Inspection steps Maintenance steps Page • 1. Filling the DHW cylinder ........... . . •...
  • Page 6: Further Details Regarding The Individual Steps

    Commissioning, inspection, maintenance Further details regarding the individual steps Filling the DHW cylinder 1. Fill the DHW cylinder from the 2. Check the fittings on the heating DHW side. water and DHW side for leaks and tighten, if required. Note If the DHW cylinder is pressurised, 3.
  • Page 7 Commissioning, inspection, maintenance Parts list Vitocell 300-B (300 litres) Please note Pointed objects or those with sharp edges will damage the internal cylinder wall. Only use plastic tools to clean the inside. 6. Use a chemical cleaning agent to remove hard deposits that cannot be removed by a high pressure cleaner.
  • Page 8 Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Returning the DHW cylinder into use 1. Reconnect the DHW cylinder to the pipework. 2. Insert new gaskets H underneath flange lid E or cylinder cap F. 3. Refit flange lid E or cylinder cap F with stainless steel circular blank G and tighten with the required torque.
  • Page 9: Parts List Vitocell 300-B (300 Litres)

    Parts lists Parts list Vitocell 300-B (300 litres) When ordering spare parts: 010 Sensor well (with item 009) Quote the type and serial no. (see 011 Sensor well thermal insulation type plate) and the item no. of the 012 Reducer required part (as per this parts list).
  • Page 10 Parts lists Parts list Vitocell 300-B (300 litres) (cont.)
  • Page 11: Parts List Vitocell 300-B (500 Litres)

    Parts lists Parts list Vitocell 300-B (500 litres) When ordering spare parts: 011 Sensor fixture Quote the type and serial no. (see 012 Sensor well (with pos. 011) type plate) and the item no. of the 013 Reducer required part (as per this parts list).
  • Page 12 Parts lists Parts list Vitocell 300-B (500 litres) (cont.)
  • Page 13: Parts List Vitocell 300-V (200 And 300 Litres)

    Parts lists Parts list Vitocell 300-V (200 and 300 litres) When ordering spare parts: 009 Sensor fixture Quote the type and serial no. (see 010 Sensor well (with item 009) type plate) and the item no. of the 011 Sensor well thermal insulation required part (as per this parts list).
  • Page 14 Parts lists Parts list Vitocell 300-V (200 and 300 litres) (cont.)
  • Page 15: Parts List Vitocell 300-V (500 Litres)

    015 Gasket 016 Dummy flange (with pos. 015) 001 Lid 017 Thermometer 002 Upper thermal insulation mat II 018 Viessmann logo 003 Lower thermal insulation mat 030 Thermometer cover 004 Hood with thermal insulation 031 Sensor well thermal insulation 005 Thermal insulation jacket...
  • Page 16 Parts lists Parts list Vitocell 300-V (500 litres) (cont.)
  • Page 17: Commissioning/Service Reports

    Commissioning/service reports Commissioning/service reports Commissioning Service Service date: Service Service Service date: Service Service Service date: Service Service Service date: Service Service Service date:...
  • Page 18: Product Parameters

    Product parameters Product parameters Vitocell 300-B Cylinder capacity kWh/24 h 1.17 1.37 Standby heat loss with 45 K temperature differential (volume standby sec- tion) (volume solar sec- tion) Vitocell 300-V Cylinder capacity Standby heat loss kWh/24 h with 45 K temperature...
  • Page 19: Accessories

    Vitocell 300-V, type EVI 200 l type EVI 300 l type EVI 500 l 11.4 Vitocell 300-B, type EVB 300 l type EVB 500 l 11.0 Capacity that can be heated with the electric im- mersion heater Vitocell 300-V, type EVI...
  • Page 20 Accessories Accessory specification (cont.) Illustration: Vitocell 300-V...
  • Page 21: Certificates

    Certificates Declaration of conformity We, Viessmann Werke GmbH & Co KG, D-35107 Allendorf, confirm as sole responsible body that the products Vitocell 300-B and Vitocell 300-V comply with the following standards: DIN 4753 AD Codes of Practice This product is designated _-0036 in accordance with the following Directives:...
  • Page 24 Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040 E-mail: info-uk@viessmann.com...

This manual is also suitable for:

Vitocell 300-vVitocell 300-b evbVitocell 300-v evi