Viessmann Vitodens 300 Service Instructions Manual page 49

Type wb3a, 49 and 66 kw gas fired wall mounted condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 300:
Table of Contents

Advertisement

Code 2
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
62:2
Circulation pump with 2
minutes run-on time
63:0
*
1
Without auxiliary
function for DHW load-
ing
65:...
Information regarding
the type of diverter
valve (not adjustable)
67:40
In conjunction with Vito-
solic solar control unit:
Set DHW value 3
6C:100
Set speed internal DHW
loading pump 100 %
6F:100
Max. output during
DHW loading 100 %,
defaulted by the boiler
coding card
71:0
*
2
DHW circulation
pump: On according to
DHW time program
72:0
*
2
DHW circulation
pump: ON according to
time program
*1
Only for constant temperature control units.
*2
Only for weather-compensated control units.
Coding
Possible change
change
Address:
value
62:0
Circulation pump without
run-on
62:1
Run-on time adjustable
to
from 1 to 15 minutes
62:15
63:1
Additional function: 1 x
daily
63:2
Every 2 to every 14 days
to
63:14
63:15
2 x daily
65:0
Without diverter valve
65:1
Diverter valve by Viess-
mann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
67:0
DHW set value adjusta-
to
ble from 0 to 60 °C
67:60
6C:0
Set speed adjustable
to
from 0 to 100 %
6C:100
6F:0
Max. output during DHW
to
loading adjustable from 0
6F:100
to 100 %
71:1
OFF during DHW loading
to set value 1
71:2
ON during DHW loading
to set value 1
72:1
OFF during DHW loading
to set value 2
72:2
ON during DHW loading
to set value 2
Coding
49