Primary Controls - Universal Audio UAD User Manual

Powered plug-ins software version 6.1
Table of Contents

Advertisement

Primary Controls

Meters
The two Meters display signal levels of the plug-in for the left and right chan-
nels. Meter ballistics of the original hardware are modeled. The Meters can
be switched to display input or output levels in peak or VU modes.
Figure 46. One side of the Ampex ATR-102 "penthouse" showing meter and I/O controls
The plug-in operates at an internal level of –12 dBFS. Therefore a digital sig-
nal with a level of –12 dB below full scale digital (0 dBFS) at the plug-in input
will equate to 0 dB on the Meters when
which is marked with the "red arrow sticker."
When
of the plug-in prior to processing.
Note:
Input/Output, these controls are permanently linked and cannot be switched
individually for the left and right channels.
Input/Output
These switches change the Meter to display levels at the input or output of the
plug-in. Input metering is a UAD-only feature which is unavailable in the orig-
inal hardware.
Input
When in Input mode, the Meter reflects the signal level after the
gain when
is set to Thru, the Meter reflects the pre-processed (raw input) signal level.
Output
When in Output mode, the meter reflects the signal level at the output of the
plug-in, which is just after the
This switch is used to change Meter behavior between Peak or VU modes.
Peak/VU
UAD Powered Plug-Ins Manual
Path Select
is set to Thru, the Meters indicate signal levels at the input
Although there are separate left/right Meter controls for VU/Peak and
Path Select
is set to Sync or Repro. In Input mode when Path Select
Reproduce
Reproduce
(output) gain.
- 151 -
is in its calibrated position,
Record
Chapter 12: Ampex ATR-102
(input)

Advertisement

Table of Contents
loading

Related Products for Universal Audio UAD

This manual is also suitable for:

Uad powered plug-ins

Table of Contents