Format
sntp unicast client poll-retry <poll-retry>
Mode
Global Config
no sntp unicast client poll-retry
This command will reset the poll retry for SNTP unicast clients to its default value.
Format
no sntp unicast client poll-retry
Mode
Global Config

sntp server

This command configures an SNTP server (a maximum of three). The optional priority can be a
value of 1-3, the version a value of 1-4, and the port id a value of 1-65535.
Format
sntp server <ipaddress|hostname> [<priority> [<version> [<portid>]]]
Mode
Global Config
no sntp server
This command deletes an server from the configured SNTP servers.
Format
no sntp server remove <ipaddress|hostname>
Mode
Global Config

clock timezone

When using SNTP/NTP time servers to update the switch's clock, the time data received from the
server is based on Coordinated Universal Time (UTC) which is the same as Greenwich Mean
Time (GMT). This may not be the time zone in which the switch is located. Use the clock
timezone command to configure a time zone specifying the number of hours and optionally the
number of minutes difference from UTC. To set the switch clock to UTC, use the no form of the
command.
Format
clock timezone zone-name +/-hours-offset [+/-minutes-offset]
Mode
Global Config
Default
no clock timezone