List Of Parameters - Omron E5ZN Operation Manual

Hide thumbs Also See for E5ZN:
Table of Contents

Advertisement

List of Parameters

6-6
List of Parameters
The following diagram shows the parameters that can be set from
the E5ZN-SDL Setting Display Unit. Some data is not displayed as
it is protected or is subject to usage conditions. A password must
be entered for access to the advanced function setting level.
The following display indicates that ch1
and ch2 have different parameter settings.
Note
1.
Indicates parameters that are displayed for pulse output models only.
2.
Indicates parameters that are displayed for analog output models only.
Advanced function
setting level
Possible by
setting
password
( 169)
Parameter
Initialize
Mode Key
Number of
Multi-SP Uses
Mode Key
Event Input
Allocation
Mode Key
Multi-SP Uses
Mode Key
SP Ramp Set Value
Mode Key
Standby Sequence
Reset Method
Mode Key
Alarm 1 Open
for Alarm
Mode Key
Alarm 1 Hysteresis
Mode Key
Alarm 2 Open
for Alarm
CH
Mode Key
Alarm 2 Hysteresis
Mode Key
Alarm 3 Open
for Alarm
CH
Mode Key
Alarm 3 Hysteresis
Mode Key
HBA Used
(See note 1.)
Mode Key
Heater Burnout
Latch
(See note 1.)
Mode Key
Heater Burnout
Hysteresis
(See note 1.)
Return to top of advanced function setting level
122
Press the
Button to switch
CH
between the data for ch1 and ch2.
ch2:
ch1:
CH
Level Key for 1 second min.
Voltage Output
Type
(See note 2.)
Mode Key
Sensor Error Indicator
(See note 2.)
Mode Key
Advanced Function
Setting Level
Mode Key
To top of initial setting level
Mode Key
MV Upper Limit
CH
Mode Key
MV Lower Limit
CH
Mode Key
Input Digital Filter
Mode Key
Additional PV Display
Mode Key
Additional
Temperature Input
Shift Value Display
Mode Key
Temperature Input
Shift Type
(See note 2.)
Mode Key
Alarm 1 Latch
Mode Key
Alarm 2 Latch
Mode Key
Alarm 3 Latch
Mode Key
Input Error Output
(See note 2.)
Mode Key
Cold Junction
Compensation
Method
Mode Key
Communication
setting level
Level Key
for less than 1 second
Initial setting level
Control Output 2
Allocation
Mode Key
Mode Key
Auxiliary Output 1
Allocation
Mode Key
Mode Key
Auxiliary Output 2
Allocation
Mode Key
Mode Key
Auxiliary Output 3
Allocation
(See note 2.)
Mode Key
Mode Key
Auxiliary Output 4
Allocation
(See note 2.)
Mode Key
Mode Key
Operation after
Power ON
Mode Key
Mode Key
OUT1 Transfer
Output Upper Limit
(See note 2.)
Mode Key
Mode Key
OUT1 Transfer
Output Lower Limit
(See note 2.)
Mode Key
Mode Key
OUT2 Transfer
Output Upper Limit
(See note 2.)
Mode Key
Mode Key
OUT2 Transfer
Output Lower Limit
(See note 2.)
Mode Key
Mode Key
SUB3 Transfer
Output Upper Limit
(See note 2.)
Mode Key
Mode Key
SUB3 Transfer
Output Lower Limit
(See note 2.)
Mode Key
Mode Key
SUB4 Transfer
Output Upper Limit
(See note 2.)
Mode Key
Mode Key
SUB4 Transfer
Output Lower Limit
(See note 2.)
Mode Key
Mode Key
Current Output
Type
(See note 2.)
Mode Key
Mode Key
Section 6-6
Communi-
cations
Data Length
Mode Key
Communi-
cations
Stop Bit
Mode Key
Communi-
cations
Parity
Mode Key
Communi-
cations
Response
Wait Time
Mode Key
Level Key
Level Key
Input Type
Scaling
Upper Limit
Scaling
Lower Limit
Decimal Point
˚C/˚F Selection
Set Point
Upper Limit
Set Point
Lower Limit
PID/OnOff
Heating Control
Period
Cooling Control
Period
Direct/Reverse
Operation
Alarm 1 Type
Alarm 2 Type
Alarm 3 Type
Control Output 1
Allocation