5-9-21 Read Controller Status - Omron E5ZN Operation Manual

Hide thumbs Also See for E5ZN:
Table of Contents

Advertisement

Commands and Responses

5-9-21 Read Controller Status

Command
Response
88
MRC
SRC
"06"
"01"
This command reads the operation status of the Temperature Controller.
The command can be used regardless of what state the Temperature Control-
ler is in.
MRC
SRC
Response code
"06"
"01"
"0000"
Operation status
"00"
Control operating for all channels (No errors in setting area 0,
executing RUN.)
"01"
Control has stopped for one channel (Errors other than errors
in setting area 0, not executing RUN.)
Related Information
7
6
5
4
3 2
0
0
0
0 0
If the Temperature Controller is in setting area 1 when the command is
received, it returns a response with "unknown" related information.
Response Code
Response
Error name
code
"1001"
Command length over
"2203"
Operation error
"0000"
Normal completion
Operation
Related
status
information
Description
1
0
Bit position
Status
Current exceeded
Current hold
Input error
The command is too long.
An error occurs in EEPROM.
The command is successfully executed.
Section 5-9
Value of bit
0
1
Not
Detected
detected
Not
Detected
detected
Not
Detected
detected
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents