Read Controller Attribute - Omron E5ZN Operation Manual

Hide thumbs Also See for E5ZN:
Table of Contents

Advertisement

Commands and Responses
Response

5-9-20 Read Controller Attribute

Command
Response
MRC
SRC
Response code
"30"
"05"
"0000"
Response code: The code shown above represents normal completion. For
details on the response code, refer to 5-7 Operation Commands .
MRC
SRC
"05"
"03"
This command reads the model name and communication buffer size of the
Temperature Controller.
The command can be used regardless of what state the Temperature Control-
ler is in.
MRC
SRC
Response code
"05"
"03"
"0000"
Model name
No. of
control
points
E5ZN-2QNH0
2
E5ZN-2QPH0
2
E5ZN-2TNH0
2
E5ZN-2TPH0
2
E5ZN-2CNF0
2
E5ZN-2CPF0
2
The model name is expressed in 10-byte ASCII.
A fixed value of "0048H" (72 bytes) for the buffer size is returned.
Response Code
Response
Error name
code
"1001"
Command length over
"2203"
Operation error
"0000"
Normal completion
Model name
Control
Auxiliary
output
output 1, 2
Pulse volt-
Transistor out-
age out-
put (sinking)
put
Pulse volt-
Transistor out-
age out-
put (sourcing)
put
Transistor
Transistor out-
output
put (sinking)
Transistor
Transistor out-
output
put (sourcing)
Linear
Transistor out-
current
put (sinking)
output
Linear
Transistor out-
voltage
put (sourcing)
output
The command is too long.
An error occurs in EEPROM.
The command is successfully executed.
Section 5-9
Buffer size
"0048"
Auxiliary
Heater
output 3, 4
burnout
alarm
Supported
Supported
Supported
Supported
Linear volt-
Not sup-
age output
ported
Linear volt-
Not sup-
age output
ported
Description
87