Emergency Stop - Omron CJ1W-NC271 - 12-2009 Operation Manual

Position control units
Table of Contents

Advertisement

Stop Functions
Type
Parame-
ter No.
Accelera-
Pn810
Exponential accelera-
tion/
tion/deceleration bias
decelera-
Pn811
Exponential accelera-
tion filters
tion/deceleration time con-
stant
Pn812
Movement average time
Axis Operating Output Memory Areas (Operating Commands)
Axis Operating Input Memory Areas (Monitoring)

10-9-3 Emergency Stop

414
Parameter name
Command
units/s
0.1 ms
0.1 ms
First-step deceleration curve operations require parameter settings for Pn80E
only. For the acceleration/deceleration curve, Pn810 and Pn811 must be set
when using an exponential curve, and Pn812 must be set when using an
S-curve.
The SMARTSTEP Junior Servo Drives do not support the following parame-
ters: Pn80D and Pn80F. They also do not support acceleration/deceleration
filters, so the filters cannot be set. A one-step linear deceleration curve is set
using only Pn80E.
Name
DECELERATION STOP
a = Beginning word of Axis Operating Output Areas specified in Common
Parameters + (Axis No. −1) × 25
Name
Receiving Command
Flag
Busy Flag
Stop Execution Flag
b = Beginning word of Axis Operating Input Areas specified in Common
Parameters + (Axis No. −1) × 25
The Stop Execution Flag turns ON when DECELERATION STOP or EMER-
GENCY STOP is received, but does not check whether the remaining pulses
in the Servo Drive are within the positioning completion range, unlike the PCU
Positioning Completed Flag in direct operation.
The Stop Execution Flag turns OFF when direct operation, jogging, speed
commands or other movement commands are executed.
The emergency stop operation cancels the operating command immediately
and stops the active axis when the EMERGENCY STOP Bit turns ON in the
Axis Operating Output Memory Area.
When EMERGENCY STOP is executed, axis operation switches to position
control mode, and stops in Servo locked status. When EMERGENCY STOP is
executed during position control, the axis operation distributes the pulses
remaining in the Servo Drive's deviation counter and then stops.
Unit
Setting
Parame-
range
ter size
0 to
2
32767
0 to 5100 2
0 to 5100 2
Word
Bits
0 → 1: Starts deceleration stop.
a
15
Word
Bits
b
00
0: Command reception enabled.
0 → 1: Command reception started.
1: Receiving command (command
reception disabled).
13
1: Axis busy (axis operation executing).
0 → 1: Stop operation completed.
15
Section 10-9
Default
W
SMART
setting
Series
STEP
Junior
0
Sup-
Not sup-
ported
ported
0
Sup-
Not sup-
ported
ported
0
Sup-
Not sup-
ported
ported
Contents
Contents