External I/O Status Bits - Omron CJ1W-NC271 - 12-2009 Operation Manual

Position control units
Table of Contents

Advertisement

Axis Operating Input Memory Areas
Forward Software Limit Flag and Reverse Software Limit Flag
Word
Bits
Function
Reverse direction
Forward Software Limit Flag
(b+1, bit 12)
Reverse Software Limit Flag
(b+1, bit 13)
Details
4-8-5

External I/O Status Bits

I/O
Word
Bits
Input
b+3
00
(PCU
01
to CPU
02
Unit)
03
04
05
06
07
08
09
10
11 to 15
b+1
12 and 13
These flags turn ON and OFF when the software limit function is enabled to
indicate the present position status for the forward/reverse software limit.
Forward Software Limit Flag
0: Within forward software limit range
1: Forward software limit range exceeded
Reverse Software Limit Flag
0: Within reverse software limit range
1: Reverse software limit range exceeded
Reverse Software Limit (Pn806)
Feedback position
Refer to 10-8 Software Limits.
The External I/O Status Bits (word b + 3) show the I/O status of the I/O signals
allocated to the Servo Drive.
b = Beginning word of Axis Operating Input Areas specified in Common
Parameters + (Axis No. −1) × 25
Category
External I/O
Forward rotation limit input
status
Reverse rotation limit input
Origin proximity input signal
Encoder Phase A input
Encoder Phase B input
Encoder Phase Z input
External latch signal 1 input
External latch signal 2 input
External latch signal 3 input
Brake output
Emergency stop input
Reserved by the system.
Bit 10 (Emergency stop input) indicates the status of the emergency stop
input signal input when using a G5-series Servo Drive, G-series Servo Drive
or SMARTSTEP Junior Servo Drive. This bit is always 0 when using a W-
series Servo Drive, which does not have an emergency stop signal.
The SMARTSTEP Junior Servo Drive does not have inputs for external latch
signals 2 and 3. When using a SMARTSTEP Junior Servo Drive, the input sta-
tus for these signals will always be 0.
Forward Software Limit (Pn804)
Name
Returns the status of I/O signals
for each axis.
1: Signal valid
0: Signal invalid
The external I/O status shows the
enabled/disabled status of signals
used for PCU control.
This status is different from the
electrical ON/OFF status of the I/O
signals.
Section 4-8
Forward direction
Function
211