List of Parameters
Param-
Parame-
Param-
eter No.
ter name
eter
size
Pn804
Forward
4
software
limit
Pn806
Reverse
4
software
limit
Pn80B
Linear
2
accelera-
tion con-
stant
Pn80E
Linear
2
decelera-
tion con-
stant
Pn814
Final travel
4
distance
for exter-
nal posi-
tioning
Contents
Digit
Name
Set-
No.
ting
Sets the software limit for the positive direction.
Sets the software limit for the negative direction.
Sets the acceleration constant for the acceleration/
deceleration curves for positioning.
Sets the deceleration constant for the acceleration/
deceleration curves for positioning.
Sets the distance from the external signal input posi-
tion when external positioning is executed.
Default
Unit
setting
Explanation
1,073,7
Com-
41,823
mand
unit
−1,073,
Com-
741,823
mand
unit
100
×10,0
00
com-
mand
units/
2
s
100
×10,0
00
com-
mand
units/
2
s
100
Com-
mand
unit
Appendix B
Setting
Enable
Details

range

setting
−1,073,
Online
---
741,823
to
1,073,7
41,823
−1,073,
Online
---
741,823
to
1,073,7
41,823
1 to
Online
Set-
65535
tings
can be
change
d when
the
axes
are
stopped
(Busy
Flag for
each
axis =
0).
1 to
Online
Set-
65535
tings
can be
change
d when
the
axes
are
stopped
(Busy
Flag for
each
axis =
0).
−1,073,
Online
Set-
741,823
tings
to
can be
1,073,7
change
41,823
d when
the
axes
are
stopped
(Busy
Flag for
each
axis =
0).
595