Ing Com - Omron CJ1W-NC271 - 12-2009 Operation Manual

Position control units
Table of Contents

Advertisement

List of Parameters
Param-
Parame-
Param-
eter No.
ter name
eter
size
Pn504
Position-
2

ing com-

pletion
range 2
Pn505
Deviation
2
counter
overflow
level
Pn506
Brake tim-
2
ing 1
Pn507
Brake
2
command
speed
Pn508
Brake tim-
2
ing 2
Pn509
Momen-
2
tary hold
time
558
Contents
Digit
Name
Set-
No.
ting
Sets the proximity range for the Positioning Proximity
Flag.
Sets the detection level for the deviation counter over
alarm.
Sets the delay from the brake command to the Servo-
motor turning OFF.
Sets the rotation speed for outputting the brake com-
mand.
Sets the delay from the Servomotor turning OFF to
the brake command output.
Sets the time during which alarm detection is disabled
when a power failure occurs.
Default
Unit
setting
Explanation
3
Com-
mand
unit
×256
1024
pulses
×10
0
ms
100
r/min
×10
50
ms
20
ms
Appendix B
Setting
Enable
Details
range
setting
1 to 250 Online
---
1 to
Online
---
32767
0 to 50
Online
---
0 to
Online
---
10000
10 to
Online
---
100
20 to
Online
---
1000

Advertisement

Table of Contents
loading

Table of Contents